CEBORA S.p.A. 13.302.047 21/12/00SPOT 3500POWER SOURCE art. 2150SERVICE MANUAL
CEBORA S.p.A. 103.302.047 21/12/00Correct?Correct?3.3.2 - Power source powered, the start button produces no effect (temperature check).GUN THERMOSTA
CEBORA S.p.A. 113.302.047 21/12/00Correct?Correct?3.3.3 - In open circuit operation, the output voltage is not regular.OPEN CIRCUIT OUTPUT VOLTAGE TE
CEBORA S.p.A. 123.302.047 21/12/00Correct?3.3.4 - In resistive load operation, the output voltage is not regular.NOTEFor the following tests use a re
CEBORA S.p.A. 133.302.047 21/12/00Correct?AUTOMATIC SINGLE STROKE OPERATING MODE TEST.q Switch (1) in automatic mode (lever to the left), switch (11)
CEBORA S.p.A. 143.302.047 21/12/00Correct?3.3.5 - In actual working conditions (thus with high currents), the welding quality is notsatisfactory.NOTEI
CEBORA S.p.A. 153.302.047 21/12/004 - COMPONENTS LIST4.1 - Power source art. 2150 : see file ESP2150.pdf enclosed at the end of the manual.4.2 - Comp
CEBORA S.p.A. 163.302.047 21/12/005 - ELECTRICAL DIAGRAMS5.1 - Power source art. 2150: see file SCHE2150.pdf enclosed at the end of the manual.5.2 -
CEBORA S.p.A. 173.302.047 21/12/005.2.4 - Output voltage, pulse train mode (par. 3.3.3, 3.3.4).5.2.5 - Output voltage, single stroke mode (par. 3.3.
CEBORA S.p.A. 183.302.047 21/12/005.3 - Control board (27) code 5.600.857.5.3.1 - Topographical drawing.5.3.2 - Connector table.Conn. Terminals Func
CEBORA S.p.A. 23.302.047 21/12/00CONTENTS1 - GENERAL INFORMATION 31.1 - Introduction. 31.2 - General service policy. 31.3 - Safety information. 31.4 -
CEBORA S.p.A. 33.302.047 21/12/001 - GENERAL INFORMATION1.1 - Introduction.The purpose of this manual is to train personnel assigned to carry out mai
CEBORA S.p.A. 43.302.047 21/12/002 - SYSTEM DESCRIPTION2.1 - Introduction.The SPOT 3500 is a multi-function system for welding, spot-welding, warming
CEBORA S.p.A. 53.302.047 21/12/00the previous time, before the pause. This generating cycle is automatically repeated as long asthe start button is he
CEBORA S.p.A. 63.302.047 21/12/003 - MAINTENANCEWARNINGSANY INTERNAL INSPECTIONS OR REPAIRS MUST BE CARRIED OUT BY QUALIFIEDPERSONNEL.DISCONNECT THE
CEBORA S.p.A. 73.302.047 21/12/00Correct?Correct?Correct?Correct?Correct?3.2.2 - Starting the power source.q System shut off and disconnected from t
CEBORA S.p.A. 83.302.047 21/12/00Correct?3.3 - Troubleshooting.WARNINGSANY INTERNAL INSPECTIONS OR REPAIRS MUST BE CARRIED OUT BY QUALIFIEDPERSONNEL.B
CEBORA S.p.A. 93.302.047 21/12/00Correct?Correct?CONTROL BOARD (27) POWER SUPPLY TEST.q Control board (27), connector CN4, terminals 1 and 5 = 380/41
Ok
Ok